Muon system simulation
UglovTimofey (Talk | contribs) m (→Muon track smearing due to the multiple scattering) |
UglovTimofey (Talk | contribs) m |
||
Line 51: | Line 51: | ||
[[File:Tau 3.55 field off smearing.png]] | [[File:Tau 3.55 field off smearing.png]] | ||
+ | |||
+ | ====Muon id feasibility study==== | ||
+ | |||
+ | With the setup, described above, Monte Carlo simulation of the muon events for the 1st and 7th gap of absorber is shown. The smearing along Z axis is due to the multiple scattering on the calorimeter, magnet and absorber. Upper pictures corresponds to the energy-weighted position of the the hit, lower to the true position of muon/pion, respectively. The simulated physical process <math>e^+e^- \to J/\psi \to \mu^+ \mu^-</math> at E=3.096 GeV. | ||
+ | |||
+ | [[File:Muon jpsi field off layers.png]] | ||
+ | |||
+ | The same for process <math>e^+e^- \to \tau^+ \tau^-</math> at E=3.3.55GeV. | ||
+ | |||
+ | [[File:Tau 3.55 field off layers.png]] |
Revision as of 08:49, 13 November 2018
Contents |
This page is dedicated to the sketch standalone simulation of the SCT detector based on pure Geant4
One of the most important and urgent tasks for muon system technology choice and further optimization is to create a fast and reliable simulation tool. Optimal toolkit in this case is pure Geant4 simulation with simplified geometry and physics lists, able to produce fast results and estimate main parameters and characteristics of the detector.
Tasks for the 0.1 version of the simulation tools
- Create geant4-based geometry description reflecting all main features influencing muon-related physics. The model are to be extendible to describe muon detector in detail if needed.
- Estimate basic features of the interacting muons (despite of the detector technology choice):
- Muon smearing due to the multiple scattering (depending of the muon energy, direction and/or specific production process; magnetic field ON/OFF)
- Desirable thickness of the muon system to reach maximal muon detection efficiency
- Muon/pion separation: decay point (detector layer) for the muons and pions of the same momentum, feasibility do distinguish processes based on this information
- Feasibility to distinguish pion kink: distinguish muons originated from the primary vertex and produced in the pion decays.
The geometry used in version 0.1 simulation
The following geometry is based mostly on the this drawings.
For simplicity, only the barrel part of the detector was simulated. The full simulation is possible, but not urgent for the first estimation.
- The following parts of the detector were simulated:
- CsI calorimeter (inner radius 1090mm, thickness 297.6 mm, which corresponds to 16 X0)
- Magnet coil (inner radius 1610mm, thickness 14.4 mm of copper, which corresponds to 1 X0)
- 9 iron absorber layers in octant geometry (see the drawings). The distance to the innermost layer is 1900mm from the beamline, the thickness of the absorber layers 30 mm,30 mm,30 mm,40 mm,40 mm,80 mm,80 mm,80 mm, respectively, which roughly corresponds to 1.7 X0, 1.7 X0, 1.7 X0, 2.3 X0, 2.3 X0, 4.5 X0, 4.5 X0, 4.5 X0.
- The 30 mm gaps between the absorber layers could be filled with organic scintillator for the energy measurement (not needed for now)
- Internal elements of the detector are estimated to give from 0.35 X0 to 0.6 X0 and are neglected in this study
- Magnetic field is NOT simulated (could be turned on if needed, though)
- Green: CsI calorimeter
- Violet: Cu magnet coil
- White: Fe absorber layers
- Yellow: Organic scintillator gaps
The source
Muons and pions were simulated as particles originated from the primary vertex according to the various physical distribution, taken from these samples. To compare detector response in case of pions and muons, pion and muon of the same sign were generated in the same event with identical momenta. During the event reconstruction all hits were categorized according to the original particle.
Results
Muon track smearing due to the multiple scattering
One of the base characteristics of the muon system is spacial resolution. Since all charged tracks are subjected to the multiple scattering on the material of the inner detectors and absorber, and soft tracks scatters stronger, the use of the muon system as tracking detector is questionable. For the muon identification purposes high spacial resolution is not needed, the optimal value should be of order of the scattering spot.
With the setup, described above, Monte Carlo simulation of the muon events for the 1st and 7th gap of absorber is shown. The smearing along Z axis is due to the multiple scattering on the calorimeter, magnet and absorber. Upper pictures corresponds to the energy-weighted position of the the hit, lower to the true position of muon/pion, respectively. The simulated physical process at E=3.096 GeV.
The same for process at E=3.3.55GeV.
Muon id feasibility study
With the setup, described above, Monte Carlo simulation of the muon events for the 1st and 7th gap of absorber is shown. The smearing along Z axis is due to the multiple scattering on the calorimeter, magnet and absorber. Upper pictures corresponds to the energy-weighted position of the the hit, lower to the true position of muon/pion, respectively. The simulated physical process at E=3.096 GeV.
The same for process at E=3.3.55GeV.